Commissioning and implementation of a pencil-beam algorithm with a Lorentz correction as a secondary dose calculation algorithm for an Elekta Unity 1.5T MR linear accelerator.
Taneja S, Wang H, Barbee DL, Galavis P, Sosa MS, Byun D, Zelefsky M, Chen T. Commissioning and implementation of a pencil-beam algorithm with a Lorentz correction as a secondary dose calculation algorithm for an Elekta Unity 1.5T MR linear accelerator. J Appl Clin Med Phys 2024, e14590. PMID: 39625056, DOI: 10.1002/acm2.14590.Peer-Reviewed Original ResearchImplementation of an ionization chamber array for linear accelerator monthly dosimetry QA.
Taneja S, Barbee DL. Implementation of an ionization chamber array for linear accelerator monthly dosimetry QA. J Appl Clin Med Phys 2024, 25: e14433. PMID: 38923344, DOI: 10.1002/acm2.14433.Peer-Reviewed Original ResearchImplementation of a Stereoscopic Camera System for Clinical Electron Simulation and Treatment Planning.
Taneja S, Barbee DL, Cohen RF, Malin M. Implementation of a Stereoscopic Camera System for Clinical Electron Simulation and Treatment Planning. Pract Radiat Oncol 2024, 14: e291-e300. PMID: 38325547, DOI: 10.1016/j.prro.2024.01.005.Peer-Reviewed Original Research
2022
Accelerated partial breast irradiation in early stage breast cancer.
Galavis PE, Abeloos CH, Cheng PC, Hitchen C, McCarthy A, Purswani JM, Shah B, Taneja S, Gerber NK. Accelerated partial breast irradiation in early stage breast cancer. Front Oncol 2022, 12: 1049704. PMID: 36439449, DOI: 10.3389/fonc.2022.1049704.Peer-Reviewed Original ResearchFive-Fraction Prone Accelerated Partial Breast Irradiation: Long-Term Oncologic, Dosimetric, and Cosmetic Outcome.
Shah BA, Xiao J, Oh C, Taneja S, Barbee D, Maisonet O, Huppert N, Perez C, Gerber NK. Five-Fraction Prone Accelerated Partial Breast Irradiation: Long-Term Oncologic, Dosimetric, and Cosmetic Outcome. Pract Radiat Oncol 2022, 12: 106-112. PMID: 34474168, DOI: 10.1016/j.prro.2021.08.009.Peer-Reviewed Original Research
2021
Automatic treatment planning for VMAT-based total body irradiation using Eclipse scripting.
Teruel JR, Taneja S, Galavis PE, Osterman KS, McCarthy A, Malin M, Gerber NK, Hitchen C, Barbee DL. Automatic treatment planning for VMAT-based total body irradiation using Eclipse scripting. J Appl Clin Med Phys 2021, 22: 119-130. PMID: 33565214, DOI: 10.1002/acm2.13189.Peer-Reviewed Original Research
2020
Measurement of the Energy Spectrum of a 6 MV Linear Accelerator Using Compton Scattering Spectroscopy and Monte Carlo-Generated Corrections
. Taneja, LJ. Bartol, W. Culberson, LA. DeWerd. “Measurement of the energy spectrum of a 6 MV linear accelerator using Compton Scattering spectroscopy and Monte-Carlo generated corrections.” IJMPCERO. 2020, 9(4), 186-200Peer-Reviewed Original ResearchCBCT image quality QA: Establishing a quantitative program.
Taneja S, Barbee DL, Rea AJ, Malin M. CBCT image quality QA: Establishing a quantitative program. J Appl Clin Med Phys 2020, 21: 215-225. PMID: 33078562, DOI: 10.1002/acm2.13062.Peer-Reviewed Original ResearchWhole breast irradiation with high tangents in the prone position
Shaikh, Fauzia AU - Tam, Moses AU - Taneja, Sameer AU - Huppert, Nelly AU - McCarthy, Allison AU - Hitchen, Christine AU - Maisonet, Olivier AU - Perez, Carmen AU - Barbee, David AU - Gerber, Naamit Kurshan PY - 2020 DA - 2020/12/01 TI - Whole breast irradiation with high tangents in the prone position JO - Journal of Radiation Oncology SP - 147 EP - 154 VL - 9 IS - 3 AB - Extending the superior border of the breast tangent fields to include the low axilla is a technique employed to target the axillary lymph node (LN) without adding additional fields. This technique, commonly referred to as high tangents, is typically done in the supine position. The feasibility of delivering high tangents in the prone position has never been reported. SN - 1948-7908 UR - https://doi.org/10.1007/s13566-020-00433-z DO - 10.1007/s13566-020-00433-z ID - Shaikh2020 ER -Peer-Reviewed Original ResearchUse of a 2-dimensional ionization chamber array to measure head leakage of a Varian Truebeam® linear accelerator
S. Taneja, JR. Teruel, L. Hu, J. Xue, D. Barbee, “Use of a 2-dimensional ionization chamber array to measure head leakage of a Varian Truebeam® linear accelerator.” IJMPCERO. August 2020, 9(3), 87-95Peer-Reviewed Original Research